Current
SCPI Commands :
FETCh:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:PSTeps:CURRent
READ:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:PSTeps:CURRent
CALCulate:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:PSTeps:CURRent
- class CurrentCls[source]
Current commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- calculate(carrier=Carrier.Default) List[float][source]
# SCPI: CALCulate:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:PSTeps:CURRent value: List[float or bool] = driver.wcdmaMeas.tpc.carrier.trace.psteps.current.calculate(carrier = repcap.Carrier.Default)
Return the values of the power steps trace per carrier. Each power step is calculated as the difference between the UE power of a slot and the UE power of the preceding slot. For the first measured slot, a 0 is returned. You can query the number of measured slots using the CONFigure:WCDMa:MEAS:TPC:…:MLENgth? command of the used measurement mode. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Suppressed linked return values: reliability
- param carrier:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return:
power_steps: (float or boolean items) N power step results, one per measured slot Power step result number m indicates the difference between the UE power results number m and number m-1. The first power step result equals NCAP.
- fetch(carrier=Carrier.Default) List[float][source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:PSTeps:CURRent value: List[float] = driver.wcdmaMeas.tpc.carrier.trace.psteps.current.fetch(carrier = repcap.Carrier.Default)
Return the values of the power steps trace per carrier. Each power step is calculated as the difference between the UE power of a slot and the UE power of the preceding slot. For the first measured slot, a 0 is returned. You can query the number of measured slots using the CONFigure:WCDMa:MEAS:TPC:…:MLENgth? command of the used measurement mode. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Suppressed linked return values: reliability
- param carrier:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return:
power_steps: N power step results, one per measured slot Power step result number m indicates the difference between the UE power results number m and number m-1. The first power step result equals NCAP.
- read(carrier=Carrier.Default) List[float][source]
# SCPI: READ:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:PSTeps:CURRent value: List[float] = driver.wcdmaMeas.tpc.carrier.trace.psteps.current.read(carrier = repcap.Carrier.Default)
Return the values of the power steps trace per carrier. Each power step is calculated as the difference between the UE power of a slot and the UE power of the preceding slot. For the first measured slot, a 0 is returned. You can query the number of measured slots using the CONFigure:WCDMa:MEAS:TPC:…:MLENgth? command of the used measurement mode. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Suppressed linked return values: reliability
- param carrier:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return:
power_steps: N power step results, one per measured slot Power step result number m indicates the difference between the UE power results number m and number m-1. The first power step result equals NCAP.