Maximum

SCPI Commands :

READ:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:MAXimum
FETCh:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:MAXimum
CALCulate:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:MAXimum
class MaximumCls[source]

Maximum commands group definition. 3 total commands, 0 Subgroups, 3 group commands

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Pwr_Steps_0_Db: float or bool: No parameter help available

  • Pwr_Steps_B_1_Db: float or bool: No parameter help available

  • Pwr_Steps_Cm_1_Db: float or bool: No parameter help available

  • Pwr_Steps_Group_A: float or bool: No parameter help available

  • Pwr_Steps_Group_B: float or bool: No parameter help available

  • Pwr_Steps_Group_C: float or bool: No parameter help available

  • Start_Slot_Group_A: float or bool: No parameter help available

  • Pwr_Steps_Eg: float or bool: No parameter help available

  • Pwr_Steps_Fh: float or bool: No parameter help available

  • Pwr_Steps_Group_Eg: float or bool: No parameter help available

  • Pwr_Steps_Group_Fh: float or bool: No parameter help available

  • Start_Slot_Group_Eg: float or bool: No parameter help available

  • Start_Slot_Group_Fh: float or bool: No parameter help available

  • Pwr_Steps_Up: float or bool: No parameter help available

  • Pwr_Steps_Down: float or bool: No parameter help available

  • Epwr_Steps_B_1_D_B: enums.ResultStatus2: No parameter help available

  • Epwr_Steps_Cm_1_D_B: enums.ResultStatus2: No parameter help available

  • Epwr_Steps_Eg: enums.ResultStatus2: No parameter help available

  • Epwr_Steps_Fh: enums.ResultStatus2: No parameter help available

class ResultData[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Pwr_Steps_0_Db: float: No parameter help available

  • Pwr_Steps_B_1_Db: float: No parameter help available

  • Pwr_Steps_Cm_1_Db: float: No parameter help available

  • Pwr_Steps_Group_A: float: No parameter help available

  • Pwr_Steps_Group_B: float: No parameter help available

  • Pwr_Steps_Group_C: float: No parameter help available

  • Start_Slot_Group_A: int: No parameter help available

  • Pwr_Steps_Eg: float: No parameter help available

  • Pwr_Steps_Fh: float: No parameter help available

  • Pwr_Steps_Group_Eg: float: No parameter help available

  • Pwr_Steps_Group_Fh: float: No parameter help available

  • Start_Slot_Group_Eg: int: No parameter help available

  • Start_Slot_Group_Fh: int: No parameter help available

  • Pwr_Steps_Up: float: No parameter help available

  • Pwr_Steps_Down: float: No parameter help available

  • Init_Pwr_Step: float: No parameter help available

  • Rpwr_Steps: float: No parameter help available

  • Rpwr_Steps_Group: float: No parameter help available

  • Pwr_Step_Ncm_Cm: float: No parameter help available

  • Pwr_Step_Cm_Ncm: float: No parameter help available

  • Epwr_Steps_B_1_D_B: float: No parameter help available

  • Epwr_Steps_Cm_1_D_B: float: No parameter help available

  • Epwr_Steps_Eg: float: No parameter help available

  • Epwr_Steps_Fh: float: No parameter help available

calculate(carrier=Carrier.Default) CalculateStruct[source]
# SCPI: CALCulate:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:MAXimum
value: CalculateStruct = driver.wcdmaMeas.tpc.carrier.psteps.maximum.calculate(carrier = repcap.Carrier.Default)

Return the power step and power step group single value results per carrier. The minimum, maximum and average results can be retrieved. The command returns all parameters listed below, independent of the selected TPC setup. However, only for some of the parameters measured values are available. For the other parameters, only an indicator is returned (e.g. NAV) . ‘Step A’ to ‘step H’ refer to the test steps of the Inner Loop Power Control mode (results <2_Step0dB_ABC> to <14_StartFH> and <22_EPStepsB1dB> to <25_EPStepsFH>) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return:

structure: for return value, see the help for CalculateStruct structure arguments.

fetch(carrier=Carrier.Default) ResultData[source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:MAXimum
value: ResultData = driver.wcdmaMeas.tpc.carrier.psteps.maximum.fetch(carrier = repcap.Carrier.Default)

Return the power step and power step group single value results per carrier. The minimum, maximum and average results can be retrieved. The command returns all parameters listed below, independent of the selected TPC setup. However, only for some of the parameters measured values are available. For the other parameters, only an indicator is returned (e.g. NAV) . ‘Step A’ to ‘step H’ refer to the test steps of the Inner Loop Power Control mode (results <2_Step0dB_ABC> to <14_StartFH> and <22_EPStepsB1dB> to <25_EPStepsFH>) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return:

structure: for return value, see the help for ResultData structure arguments.

read(carrier=Carrier.Default) ResultData[source]
# SCPI: READ:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:MAXimum
value: ResultData = driver.wcdmaMeas.tpc.carrier.psteps.maximum.read(carrier = repcap.Carrier.Default)

Return the power step and power step group single value results per carrier. The minimum, maximum and average results can be retrieved. The command returns all parameters listed below, independent of the selected TPC setup. However, only for some of the parameters measured values are available. For the other parameters, only an indicator is returned (e.g. NAV) . ‘Step A’ to ‘step H’ refer to the test steps of the Inner Loop Power Control mode (results <2_Step0dB_ABC> to <14_StartFH> and <22_EPStepsB1dB> to <25_EPStepsFH>) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return:

structure: for return value, see the help for ResultData structure arguments.