StandardDev

SCPI Commands :

READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:UEPower:SDEViation
FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:UEPower:SDEViation
class StandardDevCls[source]

StandardDev commands group definition. 2 total commands, 0 Subgroups, 2 group commands

fetch(carrier=Carrier.Default) List[float][source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:UEPower:SDEViation
value: List[float] = driver.wcdmaMeas.multiEval.carrier.trace.uePower.standardDev.fetch(carrier = repcap.Carrier.Default)

Returns the values of the UE power traces for up to 120 slots. Each current value is averaged over a half-slot or a full-slot, depending on the measurement period (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas.MultiEval.Mperiod. modulation) . The number of results depends on the measurement length (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas. MultiEval.msCount) . The results of the current, average, minimum, maximum and standard deviation traces can be retrieved. The minimum and standard deviation trace cannot be displayed at the GUI.

Suppressed linked return values: reliability

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return:

ue_power: One result per measured slot or half-slot

read(carrier=Carrier.Default) List[float][source]
# SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:UEPower:SDEViation
value: List[float] = driver.wcdmaMeas.multiEval.carrier.trace.uePower.standardDev.read(carrier = repcap.Carrier.Default)

Returns the values of the UE power traces for up to 120 slots. Each current value is averaged over a half-slot or a full-slot, depending on the measurement period (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas.MultiEval.Mperiod. modulation) . The number of results depends on the measurement length (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas. MultiEval.msCount) . The results of the current, average, minimum, maximum and standard deviation traces can be retrieved. The minimum and standard deviation trace cannot be displayed at the GUI.

Suppressed linked return values: reliability

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return:

ue_power: One result per measured slot or half-slot