Minimum

SCPI Commands :

READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:CDPower:EDPDch<nr>:MINimum
FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:CDPower:EDPDch<nr>:MINimum
class MinimumCls[source]

Minimum commands group definition. 2 total commands, 0 Subgroups, 2 group commands

fetch(carrier=Carrier.Default, edpdChannel=EdpdChannel.Default) List[float][source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:CDPower:EDPDch<nr>:MINimum
value: List[float] = driver.wcdmaMeas.multiEval.carrier.trace.cdPower.edpdch.minimum.fetch(carrier = repcap.Carrier.Default, edpdChannel = repcap.EdpdChannel.Default)

Returns the values of the RMS CDP vs slot traces for the E-DPDCH 1 to 4. Each current value is averaged over a half-slot or a full-slot, depending on the measurement period (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas.MultiEval.Mperiod. modulation) . The number of results depends on the measurement length (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas. MultiEval.msCount) . The results of the current, average, minimum, maximum and standard deviation traces can be retrieved. The standard deviation trace cannot be displayed at the GUI.

Suppressed linked return values: reliability

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

param edpdChannel:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Edpdch’)

return:

edpdch: RMS CDP trace results, one result per measured slot or half-slot

read(carrier=Carrier.Default, edpdChannel=EdpdChannel.Default) List[float][source]
# SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:TRACe:CDPower:EDPDch<nr>:MINimum
value: List[float] = driver.wcdmaMeas.multiEval.carrier.trace.cdPower.edpdch.minimum.read(carrier = repcap.Carrier.Default, edpdChannel = repcap.EdpdChannel.Default)

Returns the values of the RMS CDP vs slot traces for the E-DPDCH 1 to 4. Each current value is averaged over a half-slot or a full-slot, depending on the measurement period (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas.MultiEval.Mperiod. modulation) . The number of results depends on the measurement length (see method RsCMPX_WcdmaMeas.Configure.WcdmaMeas. MultiEval.msCount) . The results of the current, average, minimum, maximum and standard deviation traces can be retrieved. The standard deviation trace cannot be displayed at the GUI.

Suppressed linked return values: reliability

param carrier:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

param edpdChannel:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Edpdch’)

return:

edpdch: RMS CDP trace results, one result per measured slot or half-slot