OcInfo
SCPI Commands :
READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:RCDerror:OCINfo
FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:RCDerror:OCINfo
- class OcInfoCls[source]
OcInfo commands group definition. 2 total commands, 0 Subgroups, 2 group commands
- class ResultData[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
State: List[enums.State]: State of the channel OFF: Channel off since start of measurement VAR: The channel has been on and off. ON: Channel on since start of measurement
Spreading_Factor: List[enums.SpreadingFactorB]: Spreading factor of the channel 2 | 4 | 8 | 16 | 32 | 64 | 128 | 256: constant spreading factor V2 | V4 | V8 | V16 | V32 | V64 | V128 | V256: varying spreading factor, indicates the smallest occurred value
Modulation: List[enums.Modulation]: Modulation format of the channel BPSK: Constantly BPSK modulated 4PAM: Constantly 4PAM modulated 4PVar: BPSK and 4PAM occurred
- fetch(carrier=Carrier.Default) ResultData[source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:RCDerror:OCINfo value: ResultData = driver.wcdmaMeas.multiEval.carrier.rcdError.ocInfo.fetch(carrier = repcap.Carrier.Default)
- Returns the overall channel information for the RCDE measurement. This information is determined from all measured slots.
INTRO_CMD_HELP: The parameters <State>, <SpreadFactor> and <Modulation> are returned for the individual channels:
Values 2 to 4: DPCCH
Values 5 to 7: DPDCH
Values 8 to 10: HSDPCCH
Values 11 to 13: EDPCCH
Values 14 to 16: EDPDCH1
Values 17 to 19: EDPDCH2
Values 20 to 22: EDPDCH3
Values 23 to 25: EDPDCH4
- param carrier:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return:
structure: for return value, see the help for ResultData structure arguments.
- read(carrier=Carrier.Default) ResultData[source]
# SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:RCDerror:OCINfo value: ResultData = driver.wcdmaMeas.multiEval.carrier.rcdError.ocInfo.read(carrier = repcap.Carrier.Default)
- Returns the overall channel information for the RCDE measurement. This information is determined from all measured slots.
INTRO_CMD_HELP: The parameters <State>, <SpreadFactor> and <Modulation> are returned for the individual channels:
Values 2 to 4: DPCCH
Values 5 to 7: DPDCH
Values 8 to 10: HSDPCCH
Values 11 to 13: EDPCCH
Values 14 to 16: EDPDCH1
Values 17 to 19: EDPDCH2
Values 20 to 22: EDPDCH3
Values 23 to 25: EDPDCH4
- param carrier:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return:
structure: for return value, see the help for ResultData structure arguments.